FBX

Self-regulating heating cable for high temperature process flow control

Details

Freeze protection for various pipepline under steam purging process Temperature maintenance for petrochemical and gas plant Medium or heavy duty heat-up process ex) hopper heater

Max. maintain temperature (Power-on) 150℃ (302°F) Max. withstand temperature (Power-off) 200℃ (392°F) Min. installation temperature -60℃ Temperature classification ( T- rating ) – FBX15x, 30x, 45x : T3 (200℃) – FBX60x : T2 (220℃) Rated voltage : 100 ~ 120 Vac, 200 ~ 277 Vac Rated power output : 15, 30, 45 and 60 watt/m@10℃ Dimension(nom.) : 12.2mm x 4.8mm Bus wire – ASTM B355 Class 2 NPC AWG16 Outer jacket – Fluoropolymer(CT) : Exposure to organic chemicals or corrosives

No overheating or burn even while overlapping each other It self-regulates thermal performance in response to temperature It can be cut to any length to suit any installation condition Independent heat output control along the length Soft power switching for energy save and for longer service life Easy termination for power connection and splicing

FBL   30   2   –   C    T

ⓐ        ⓑ  ⓒ              ⓓ

 

ⓐ Model

ⓑ Rated Output 15, 30, 45 and 60 watt/m@10˚C

ⓒ Rated Voltage 1 : 100 ~ 120 Vac 2 : 200 ~ 277 Vac

ⓓ Outer Jacket T : Fluoropolymer

 

 

   

Product Image

Power Output Graph

Circuit Breaker Selection